— Lighting

Solar Power

Servo Motor

Insulation


Lighting

Temperature Management

Water Management

Waste Management

Current Project

Energy Saving And Payback Plan (Lighting)

ProjectsPurposeActual Energy Usage before Installation (monthly)KWh
KG
M3
Planned Energy Usage after Installation (monthly)KWh
KG
M3
Planned Reduction %Investment (RMB)Estimated Payback (year)Date InstalledActual Energy Usage after Installation (monthly)KWh
KG
M3
Actual vs Planned ReductionKWh
KG
M3
Achievement Rate of PlanActual Payback (year)Review Date
Installing T5 lights in general workshopEnergy saving1990
(1)
kWh676kWh0.668,0000.6Feb-20121309kWh-633kWh0.521.1Jul-2014
Installing T5 lights in computerized embroidery workshopEnergy saving1819
(2)
kWh1273kWh0.33,0000.5Feb-20121614kWh-341kWh0.381.4Jul-2014
Installing T5 lights in other areasEnergy saving6465
(3)
kWh4525
(4)
kWh0.332,0002Feb-2012No Submeter Record
Switching to LED lightsEnergy saving105kWh10kWh0.93,0003Sep-2014No Submeter Record
Installing ultrasonic lightsEnergy saving66kWh8kWh0.885401May-2012No Submeter Record
**Remarks**
(1) Not submetered; the output is based on 76 85W emergency lightings, 12 40W light tubes and 112 24W light tubes.
(2) Not submetered; the output is based on 80 40W light tubes.
(3) Not submeter; the output is based on 738 40W light tubes and 88 20W light tubes.
(4) The assumption is based on 738 28W T5 light tubes and 88 14W T5 light tubes.

Lighting Figures - 2016

DateJanFebMarAprMayJunJulAugSepOctNovDecTotal
Total1135442120311731134109412081413125712731346147614154
Computerize Embroidery Lighting86329593192784182990910919869971063111810850
Lighting2721472722462932652993222712762833583304